  1. 1. Steady State Operation and Control of Power Distribution Systems in the Presence of Distributed Generation

    Author : Ferry Viawan; Chalmers tekniska högskola; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; distance protection; stochastic assessment; voltage dip; line drop compensation; distribution systems; on-load tap changer; overcurrent protection; sensitive equipment; voltage dip immunity; voltage control; short circuit; reactive power control; pilot protection.; protection coordination; protection; Distributed Generation; losses;

    Abstract : In this thesis, the impact of distributed generation (DG) on steady state operation and control of power distribution systems is investigated. Over the last few years, a number of factors have led to an increased interest in DG schemes. DG is gaining more and more attention worldwide as an alternative to large-scale central generating stations. READ MORE

  2. 2. Voltage collapse in power systems : analysis of component related phenomena using a power system model

    Author : Magnus Gustafsson; Niclas Krantz; Chalmers tekniska högskola; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; power system model; armature current limiter; reactive power; voltage collapse; OLTC; dynamic load; active power; field current limiter; voltage stability; load modelling; on-load tap changer; voltage instability; induction motor load;

    Abstract : .... READ MORE

  3. 3. Voltage stability in power systems : load modelling based on 130kV field measurements

    Author : Gunilla Le Dous; Chalmers tekniska högskola; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; field measurements; on-load tap changer; simulations; voltage stability; load modelling; load recovery;

    Abstract : .... READ MORE

  4. 4. Voltage Stability Simulations Using Detailed Models Based on Field Measurements

    Author : Daniel Karlsson; Chalmers tekniska högskola; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; capacity limits; field measurements; dynamic load models; on-load tap-changer control system; voltage stability; simulations;

    Abstract : This dissertation deals with voltage stability simulations, including dynamic load models, on-load tap-changer control system dynamics and generator reactive power output capacity limits. The simulations are based on sequential solving of ordinary load flow cases augmented with dynamic models. READ MORE

  5. 5. Maximizing the integration of wind power in distribution system

    Author : Shemsedin Nursebo; Chalmers tekniska högskola; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; distribution system; integration issues of wind power; cost benefit analysis.; frequency of tap change; active management strategies;

    Abstract : The global installed capacity of wind power has shown a significant growth, from just 24 GW in 2001 to 283 GW in 2012. This trend is expected to continue for some years to come. Hence a significant amount of wind power needs to be connected to the electric power system. READ MORE