Search for dissertations about: "transformer model core model"

Showing result 1 - 5 of 17 swedish dissertations containing the words transformer model core model.

  1. 1. Electromagnetic transformer modelling including the ferromagnetic core

    Author : David Ribbenfjärd; Göran Engdahl; David Jiles; KTH; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; Power transformer; hysteresis; dynamic hysteresis; dynamic magnetization; eddy currents; excess losses; leakage flux; winding model; core model; magnetic measurements; magnetic materials; Electric power engineering; Elkraftteknik;

    Abstract : In order to design a power transformer it is important to understand its internal electromagnetic behaviour. That can be obtained by measurements on physical transformers, analytical expressions and computer simulations. READ MORE

  2. 2. A lumped element transformer model including core losses and winding impedances

    Author : David Ribbenfjärd; Göran Engdahl; Arvid Broddefalk; KTH; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; power transformer; hysteresis; dynamic hysteresis; eddy currents; excess eddy currents; leakage flux; winding model; core model; magnetic measurements; magnetic materials; Electrical engineering; Elektroteknik;

    Abstract : In order to design a power transformer it is important to understand its internal electromagnetic behaviour. That can be obtained by measurements on physical transformers, analytical expressions and computer simulations. READ MORE

  3. 3. An FRA Transformer Model with Application on Time Domain Reflectometry

    Author : Hanif Tavakoli; Göran Engdahl; Jonas Ekman; KTH; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; complex permeability; lumped circuit model; frequency response analysis; time domain reflectometry; high frequency modeling; transformer diagnosis; reluctance network method.;

    Abstract : Frequency response analysis (FRA) is a frequency-domain method which is used to detect mechanical faults in transformers. The frequency response of a transformer is determined by its geometry and material properties, and it can be considered as the transformer’s fingerprint. READ MORE

  4. 4. A High Frequency Transformer Winding Model for FRA Applications

    Author : Hanif Tavakoli; Göran Engdahl; Jonas Ekman; KTH; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; complex permeability; frequency response analysis; time domain reflectometry; high frequency modeling; transformer diagnosis; Electrical engineering; Elektroteknik;

    Abstract : Frequency response analysis (FRA) is a method which is used to detect mechanical faults in transformers. The FRA response of a transformer is determined by its geometry and material properties, and it can be considered as the transformer’s fingerprint. READ MORE

  5. 5. Electromagnetic Modelling of Power Transformers for Study and Mitigation of Effects of GICs

    Author : Seyedali Mousavi; Göran Engdahl; Ebrahim Rahimpour; KTH; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; transformer; hysteresis; DC magnetization; GMD; GICs; FEM; reluctance network method; low frequency transients; core losses; winding losses; eddy current losses; transformator; hysteresis; DC; likströmsmagnetisering; GMD; GIC; FEM; reluktansnätverksmodell; lågfrekventa transienter; kärnförluster; lindningsförluster; virvelströmsförluster; Electrical Engineering; Elektro- och systemteknik;

    Abstract : Geomagnetic disturbances that result from solar activities can affect technological systems such as power networks. They may cause DC currents in power networks and saturation of the core in power transformers that leads to destruction in the transformer performance. READ MORE