Search for dissertations about: "Medical Technologies"

Showing result 1 - 5 of 414 swedish dissertations containing the words Medical Technologies.

  1. 1. Hyperthermia-responsive liposomal systems

    Author : Yujia Jing; Chalmers tekniska högskola; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; NATURVETENSKAP; NATURAL SCIENCES; MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; cationic lipid; asymmetry; phospholipase; liposomes; flip-flop; hyperthermia; phase transition; supported lipid membranes; drug delivery;

    Abstract : Abstract Sophisticated liposomal systems are emerging at an increasing rate to meet the demands for multifunctional drug carriers in chemotherapies in combined with hyperthermia. For example, liposomal drug carriers for temperature-controlled drug release under hyperthermic conditions have recently been tested in clinical trials. READ MORE

  2. 2. A Segmented Silicon Strip Detector for Photon-Counting Spectral Computed Tomography

    Author : Cheng Xu; Hans Bornefalk; Mats Danielsson; Ami Altman; KTH; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; photon counting; spectral computed tomography; silicon strip detector; ASIC; energy resolution; cadmium telluride; charge sharing; Monte Carlo simulation; synchrotron;

    Abstract : Spectral computed tomography with energy-resolving detectors has a potential to improve the detectability of images and correspondingly reduce the radiation dose to patients by extracting and properly using the energy information in the broad x-ray spectrum. A silicon photon-counting detector has been developed for spectral CT and it has successfully solved the problem of high photon flux in clinical CT applications by adopting the segmented detector structure and operating the detector in edge-on geometry. READ MORE

  3. 3. Spectral Mammography with X-Ray Optics and a Photon-Counting Detector

    Author : Erik Fredenberg; Mats Danielsson; Björn Cederström; Jeffrey H. Siewerdsen; KTH; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; NATURVETENSKAP; NATURAL SCIENCES; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; mammography; x-ray optics; photon counting; spectral shaping; spectral imaging; collimation; radiation dose; signal-to-noise ratio; quantum noise; anatomical noise; spatial resolution; x-ray flux; ; TECHNOLOGY; TEKNIKVETENSKAP; Engineering physics; Teknisk fysik; Optical physics; Optisk fysik; Other engineering physics; Övrig teknisk fysik; Electrical engineering; electronics and photonics; Elektroteknik; elektronik och fotonik; Medical engineering; Medicinsk teknik; Radiological research; Radiologisk forskning;

    Abstract : Early detection is vital to successfully treating breast cancer, and mammography screening is the most efficient and wide-spread method to reach this goal. Imaging low-contrast targets, while minimizing the radiation exposure to a large population is, however, a major challenge. READ MORE

  4. 4. Development of a polymer based neural probe - How to record intracortical neural activity while minimizing the tissue response

    Author : Fredrik Ejserholm; Avdelningen för Biomedicinsk teknik; []
    Keywords : MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; Neural Probes; Electrode Modification; Polymer; Neurophysiology; OSTE ;

    Abstract : Intracortical neural probes have in the last couple of years been developed from stiff single probes to stiff multi-electrode neural probes to flexible multi-electrode neural probes. One reason for the change in design is that more than one recording/stimulation electrode, as in the case with a single wire, is needed for more advanced studies. READ MORE

  5. 5. Magnetic Resonance Imaging of the Heart : Image quality, measurement accuracy and patient experience

    Author : Britt-Marie Ahlander; Jan Engvall; Elisabeth Ericsson; Eva Maret; Marcus Carlsson; Linköpings universitet; []
    Keywords : MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; Medicine; Medicin;

    Abstract : Background: Non-invasive diagnostic imaging of atherosclerotic coronary artery disease (CAD) is frequently carried out with cardiovascular magnetic resonance imaging (CMR) or myocardial perfusion single photon emission computed tomography (MPS). CMR is the gold standard for the evaluation of scar after myocardial infarction and MPS the clinical gold standard for ischemia. READ MORE