Search for dissertations about: "Oil-impregnated pressboard paper insulation"

Found 4 swedish dissertations containing the words Oil-impregnated pressboard paper insulation.

  1. 1. Partial Discharge Signatures of Defects in Insulation Systems Consisting of Oil and Oil-impregnated Paper

    Author : Mohamad Ghaffarian Niasar; Hans Edin; Peter Werelius; KTH; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; partial discharge; transformer; oil; ageing; temperature; PD classification;

    Abstract : Partial discharge measurement is a common method for monitoring and diagnostics of power transformers, and can detect insulation malfunctions before they lead to failure. Different parameters extracted from the measured PD activity can be correlated to the PD source, and as a result it is possible to identify the PD source by analyzing the PD activity. READ MORE

  2. 2. Diagnosis of Moisture in Transformer Insulation - Application of frequency domain spectroscopy

    Author : Chandima Ekanayake; Chalmers tekniska högskola; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; moisture content; diagnostic methods; modelling; polarisation depolarisation currents PDC ; frequency domain spectroscopy FDS ; dielectric response measurements; Oil-impregnated pressboard paper insulation; Karl Fischer titration KFT ; conductivity; ageing;

    Abstract : This thesis presents application of dielectric response measurements for identifying condition of high voltage insulation in power transformers. Results of such measurements, incorporated with different modelling techniques, allow to estimate moisture content in solid part of transformer insulation. READ MORE

  3. 3. High Voltage DC-biased Oil Type Medium Frequency Transformer; A Green Solution for Series DC Wind Park Concept

    Author : Mohammad Kharezy; Chalmers tekniska högskola; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; High voltage DC; Insulation design; Offshore wind farm; Leakage inductance; High power isolated DC DC converter; Dual active bridge; Medium-frequency power transformer; Parasitic capacitance; HVDC;

    Abstract : The electric energy generated by remote offshore wind parks is transported to the consumers using high voltage submarine cables. On the generation site, such transmissions are realized today by collecting the energy produced by several wind turbines in a bulky and expensive transformer placed on a dedicated platform. READ MORE

  4. 4. Enhanced Dielectric Response Methods for the Characterization of Dielectric Materials

    Author : Jing Hao; Nathaniel Taylor; KTH; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; FDS; non-contact; dielectric response; combined AC and DC; space-charge polarization;

    Abstract : Dielectric response measurement is widely used for condition assessment of high voltage equipment and for characterizing candidate materials. Measurement with high accuracy and reliability is important in all stages of the lifetime of high voltage equipment, from manufacture to replacement decision. READ MORE