Search for dissertations about: "accuracy of ct"

Showing result 1 - 5 of 108 swedish dissertations containing the words accuracy of ct.

  1. 1. Aspects of PET-CT in prostate cancer. Protocol optimization, diagnostic accuracy, and dosimetry

    Author : Mimmi Bjöersdorff; Malmö Nuklearmedicin; []
    Keywords : MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; PET-CT; Prostatacancer; [18F]FCH; [18F]PSMA-1007; optimering; diagnostisk noggrannhet; dosimetri; PET-CT; Prostate Cancer; [18F]FCH; [18F]PSMA-1007; Optimization; Diagnostic accuracy; Dosimetric;

    Abstract : The PET-CT imaging modality is based on positron emission tomography combined with computed tomography. Before a PET-CT examination, a radioactive tracer (also called a radiopharmaceutical) is intravenously injected into the patient. PET technology images the distribution of this tracer element by detecting the decay. READ MORE

  2. 2. Diagnosis and evaluation of therapeutic response of bone metastases

    Author : Ipek Çiray; Uppsala universitet; []
    Keywords : MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; Oncology; Bone metastases; breast neoplasm; MR imaging; CT; diagnosis; therapy evaluation; Onkologi; Oncology; Onkologi; diagnostisk radiologi; Diagnostic Radiology;

    Abstract : The aim of this study was to investigate different aspects of different imaging modalities in the diagnosis of bone metastases and in the assessment of their response to therapy. The role of CT, with and without clinical information, was investigated as compared to CT-guided bone biopsy in the evaluation of suspected bone metastases. READ MORE

  3. 3. Alternative Methods for Assessment of Split Renal Function

    Author : Henrik Björkman; Anders Magnusson; Jonas Wadström; Torbjörn Andersson; Uppsala universitet; []
    Keywords : Radiology; Split renal function; Live kidney donor; CT; Renography; Dynamic MRI; Renal volume; Respiratory triggering; Radiologisk forskning;

    Abstract : Living kidney donation is a clinical situation with unique features in the sense that healthy individuals voluntarily expose themselves to certain risks and inconveniences. Therefore, eliminating as much of the associated discomfort as possible is crucial. READ MORE

  4. 4. CT colonography. Technique, diagnostic accuracy and patient acceptance

    Author : Maria H Svensson (Reutersköld); Göteborgs universitet; []
    Keywords : Colon; Rectum; Computed tomography; Three-dimensional imaging; Colorectal neoplasms; Colonic polyps; Colonoscopy; Acceptance testing; Incidental findings; Diagnostic accuracy;

    Abstract : The aim was to evaluate diagnostic potential, technical performance, and patient acceptance of CT colonography when used for detection of colorectal polyps and cancer in symptomatic patients with a high risk of colorectal neoplasia.Methods: After bowel preparation, 111 symptomatic patients underwent CT colonography followed by conventional colonoscopy. READ MORE

  5. 5. Non-enhanced single-energy computed tomography of urinary stones

    Author : Johan Jendeberg; Mats Lidén; Per Thunberg; Anders Magnusson; Örebro universitet; []
    Keywords : MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; Diagnostic; CT; urinary stone; kidney stone; urolithiasis; phlebolith; uric acid; spontaneous passage; CNN; artificial intelligence;

    Abstract : Computed tomography (CT) is the mainstay imaging method for urinary stones.The aim of this thesis was to optimize the information obtained from the initial CT scan to allow a well-founded diagnosis and prognosis, and to guide the clinician as early and as far as possible in the further treatment of urinary stone disease. READ MORE