Search for dissertations about: "fourier transform spectrometer"

Showing result 1 - 5 of 20 swedish dissertations containing the words fourier transform spectrometer.

  1. 1. Constructing and Commissioning HELIOS – A High Harmonic Generation Source for Pump-Probe Measurements with sub 50 fs Temporal Resolution : The Development of Experimental Equipment for Extreme Ultraviolet Spectroscopy

    Author : Joachim A. Terschlüsen; Johan Söderström; Margaret Murnane; Uppsala universitet; []
    Keywords : NATURVETENSKAP; NATURAL SCIENCES; NATURVETENSKAP; NATURAL SCIENCES; Angle-resolved photoemission spectroscopy; Angle resolved photoemission spectroscopy; Angle-resolved time-of-flight; Angle resolved time of flight; ARTOF; ARPES; tr-ARPES; fs; fs resolution; Fourier transform spectrometer; Fourier-transform spectrometer; Fourier transform spectroscopy; Fourier-transform spectroscopy; FTS; gas cell; high harmonic generation; laser; liquid jet; monochromator; HELIOS; HHG; off-plane mount; off plane mount; OPA; optical parametric amplifier; PCPDTBT; pulse shaping; pump probe; pump-probe measurements; pump-probe measurements; pump-probe spectroscopy; pump-probe spectroscopy; Rowland spectrometer; time-of-flight spectrometer; time of flight spectrometer; TOF; time-resolved spectroscopy; time resolved spectroscopy; time-resolved experiments; time resolved experiments; T-MOKE; tr-PES; PES; photoelectron spectroscopy; transverse magneto optical Kerr effect; transverse magneto-optical Kerr effect; ultrafast; ultra-high vacuum; ultra high vacuum; UHV; XUV; VUV; X-rays; Permalloy; magnetization dynamic; Physics with spec. in Atomic; Molecular and Condensed Matter Physics; Fysik med inriktning mot atom- molekyl- och kondenserande materiens fysik;

    Abstract : This thesis presents HELIOS, an in-house laboratory for time-resolved pump-probe spectroscopy with extreme-ultraviolet (XUV) probe radiation. A wide span of pump wavelengths can be generated using commercial laser equipment while XUV probe radiation is generated via a high harmonic generation process in a noble gas delivering probe photons with energies between 20 eV and 72 eV. READ MORE

  2. 2. Fourier transform and Vernier spectroscopy using optical frequency combs

    Author : Amir Khodabakhsh; Aleksandra Foltynowicz; Ove Axner; Frans Harren; Umeå universitet; []
    Keywords : NATURVETENSKAP; NATURAL SCIENCES; optical frequency comb spectroscopy; molecular absorption; resonant cavity; Fourier transform spectroscopy; Vernier spectroscopy; fysik; Physics;

    Abstract : Optical frequency comb spectroscopy (OFCS) combines two previously exclusive features, i.e., wide optical bandwidth and high spectral resolution, enabling precise measurements of entire molecular bands and simultaneous monitoring of multiple gas species in a short measurement time. READ MORE

  3. 3. Precision molecular spectroscopy in the near- and mid-infrared using frequency comb-based Fourier transform spectrometers

    Author : Adrian Hjältén; Aleksandra Foltynowicz; Ove Axner; Adam Fleisher; Umeå universitet; []
    Keywords : NATURVETENSKAP; NATURAL SCIENCES; optical frequency comb; molecular spectroscopy; Fourier transform spectrometer; high resolution; mid-infrared; line list; double-resonance spectroscopy; difference frequency generation; fysik; Physics;

    Abstract : Absorption spectroscopy is a powerful scientific tool for non-invasive and remote sensing applications ranging from atmospheric monitoring to astrophysics. In spectroscopic detection schemes it is necessary to have spectral models for any molecular species to be detected or quantified. READ MORE

  4. 4. Measurement of trace components in aqueous solutions with near and mid infrared Fourier transform spectroscopy

    Author : Peter Snoer Jensen; Atomfysik; []
    Keywords : NATURVETENSKAP; NATURAL SCIENCES; Near-infrared; Temperature dependency; Dual-beam; Optical null; Optimal pathlength Haemodialysis liquid; Urea; Glucose; Phosphate; Atom- och molekylärfysik; Atomic and molecular physics; Infrared; Water absorption; Fourier transform spectroscopy; Fysicumarkivet A:2003:Snoer Jensen;

    Abstract : This thesis treats various aspects of the measurement of trace components in aqueous solutions with Fourier transform infrared spectroscopy. This technique has several applications from such diverse fields as dairy industry and biomedical optics. READ MORE

  5. 5. NbN and NbTiN Hot Electron Bolometer THz Mixers

    Author : Pourya Khosropanah; Chalmers tekniska högskola; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; receiver noise; hot electron bolometer; superconducting detector; spiral antenna; NbTiN; submillimeter mixer; THz mixer; HEB; FTS; NbN; quasioptical receiver; heterodyne receiver; double slot antenna; twin slot antenna; Fourier Transform Spectrometer;

    Abstract : The thesis reports the development of Hot Electron Bolometer (HEB) mixers for radio astronomy heterodyne receivers in THz frequency range. Part of this work is the fabrication of HEB devices, which are based on NbN or NbTiN superconducting thin films (≤5 nm). They are integrated with wideband spiral or double-slot planar antennas. READ MORE