Search for dissertations about: "optimization on power transformer thesis"
Showing result 1 - 5 of 12 swedish dissertations containing the words optimization on power transformer thesis.
-
1. Process Control and Simulation of Ferromagnetic Strip in the Power Transformers and Electrical Machines Applications : Electric power systems
Abstract : This thesis investigates optimization of the control of electrical and thermal equipment by using FEM and CFD modeling in combination with dynamic simulation models. The thesis focuses on the production of electrical strips and the control system with the aim of reducing losses and improving magnetic properties. READ MORE
-
2. Design and Optimization Considerations of Medium-Frequency Power Transformers in High-Power DC-DC Applications
Abstract : Recently, power electronic converters are considered as one of the enabling technologies that can address many technical challenges in future power grids from the generation phase to the transmission and consequently distribution at different voltage levels. In contrast to the medium-power converters (5 to 100 kW) which have beenessentially investigated by the automotive and traction applications, megawatt and medium-voltage range isolated converters with a several kilohertz isolation stage,also called solid-state transformers (SST), are still in an expansive research phase. READ MORE
-
3. Dynamic Rating with Applications to Renewable Energy
Abstract : Dynamic rating (DR) of power components is a method for assessing real-time capacity of large scale power transmission and distribution devices (commonly: transmission lines, power transformers, underground cables) and using this knowledge for adjusting loading limits of these components. Dynamic rating of power lines or dynamic line rating (DLR) is a pioneering technology in the area of dynamic rating. READ MORE
-
4. Magnetizing Currents in Power Transformers : Measurements, Simulations, and Diagnostic Methods
Abstract : This thesis demonstrates a method for transformer core diagnostics. The method uses the no-load current of the transformer as an indicator, and gives different characteristic signatures for different types of faults or defects. Using the no-load current for the diagnostic gives high sensitivity. READ MORE
-
5. Effect of Dielectric and Magnetic Material Characteristics on Frequency Response of Power Transformers
Abstract : Frequency response analysis (FRA) technique has become increasingly popular for the assessment of mechanicalintegrity in power transformers. This method is based on the fact that the shape of the frequency response at higher frequencies is uniquely determined by the geometrical construction of the transformer. READ MORE