  1. 1. X-ray Phase Contrast Tomography : Setup and Scintillator Development

    Author : Hanna Dierks; NanoLund: Centre for Nanoscience; []
    Keywords : NATURVETENSKAP; NATURAL SCIENCES; x-rays; x-ray imaging; x-ray microscopy; X-ray detectors; perovskites; laboratory setups; phase contrast; μCT; scintillator; Phase contrast PC ; Tomography x-ray computed ;

    Abstract : X-ray microscopy and micro-tomography (μCT) are valuable non-destructive examination methods in many disciplines such as bio-medical research, archaeometry, material science and paleontology. Besides being implemented at synchrotrons radiation sources, laboratory setups using an X-ray tube and high-resolution scintillation detector routinely provide information on the micrometre scale. READ MORE

  2. 2. Laboratory X-Ray Phase-Contrast Imaging : Methods and Comparisons

    Author : Tunhe Zhou; Anna Burvall; Hans M. Hertz; Tim Salditt; KTH; []
    Keywords : NATURVETENSKAP; NATURAL SCIENCES; X-ray imaging; Phase-contrast; Liquid-metal-jet source; Propagation-based imaging; Grating-based imaging; Speckle-based imaging; Fysik; Physics;

    Abstract : X-ray phase-contrast imaging has seen rapid development in recent decades due to its superior performance in imaging low-absorption objects, compared to traditional attenuation x-ray imaging. Having higher demand on coherence, x-ray phase-contrast imaging is performed mostly at synchrotrons. READ MORE

  3. 3. Liquid-Jet-Target Microfocus X-Ray Sources : Electron Guns, Optics and Phase-Contrast Imaging

    Author : Tomi Tuohimaa; Hans M. Hertz; Stephen Wilkins; KTH; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; electron-impact; x-ray; brightness; liquid-jet-target; phase-contrast imaging; Engineering physics; Teknisk fysik;

    Abstract : This Thesis describes the development of an electron-impact microfocus x-ray source and its application for phase-contrast imaging. The source is based on a novel, liquid-jet target concept. Stable and continuous operation can be achieved at substantially higher electron-beam power densities than conventional solid target based systems. READ MORE

  4. 4. High-resolution biomedical phase-contrast tomography

    Author : William Twengström; Hans Hertz; Anna Burvall; Marco Stampanoni; KTH; []
    Keywords : NATURVETENSKAP; NATURAL SCIENCES; MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; x-ray; x-ray imaging; biomedical; phase contrast; tomography; zebrafish; coronary artery; virtual histology; ring artifacts; phase retrieval; mummy; Fysik; Physics;

    Abstract : Improved three-dimensional biomedical imaging can give a better understanding of tissue structure, growth and diseases. Most present imaging techniques that provide cellular spatial resolution are based on visible or infrared light. These methods cannot image deeper than a millimeter into tissue. READ MORE

  5. 5. Small-Animal Imaging with Liquid-Metal-Jet X-Ray Sources

    Author : Daniel Larsson; Hans Hertz; Anna Burvall; David Paterson; KTH; []
    Keywords : NATURVETENSKAP; NATURAL SCIENCES; X-ray; x-ray imaging; small animal; phase contrast; tomography; Fysik; Physics;

    Abstract : Small-animal x-ray imaging is an important tool for medical research. The penetration power of x-rays makes it possible to investigate the 3D structure of small animals and other thick biological samples by computed tomography (CT). READ MORE