1. Concepts for Power System Small Signal Stability Analysis and Feedback Control Design Considering Synchrophasor Measurements
Abstract : In the Nordic power network, the existence of poorly damped low-frequency inter-area oscillations (LFIOs) has long affected stability constraints, and thereby, limited power transfer capacity. Adequate damping of inter-area modes is, thus, necessary to secure system operation and ensure system reliability while increasing power transfers. READ MORE
-
2. PMU-based State Estimation for Hybrid AC and DC Grids
Abstract : Power system state estimation plays key role in the energy management systems(EMS) of providing the best estimates of the electrical variables in the grid that arefurther used in functions such as contingency analysis, automatic generation control,dispatch, and others. The invention of phasor measurement units (PMUs) takes thepower system operation and control into a new era, where PMUs’ high reportingrate and synchronization characteristics allow the development of new wide-areamonitoring, protection, and control (WAMPAC) application to enhance the grid’sresiliency. READ MORE
-
3. Data Quality in Wide-Area Monitoring and Control Systems : PMU Data Latency, Completness, and Design of Wide-Area Damping Systems
Abstract : The strain on modern electrical power system operation has led to an ever increasing utilization of new Information Communication Technology (ICT) systems to enhance the reliability and efficiency of grid operation. Among these proposals, Phasor Measurement Unit (PMU)-based Wide-Area Monitoring and Control (WAMC) systems have been recognized as one of the enablers of “Smart Grid”, particularly at the transmission level, due to their capability to improve the real-time situational awareness of the grid. READ MORE
-
4. Security of Time Synchronization for PMU-based Power System State Estimation: Vulnerabilities and Countermeasures
Abstract : Phasor Measurement Units (PMUs) constitute an emerging technology that is essential for various smart grid applications such as phase angle monitoring, power oscillation damping, fault localization, and linear state estimation. To obtain precise PMU measurements of voltage and current phasors, time synchronization in the order of 1 microsecond is typically required. READ MORE
-
5. Synchrophasor based Steady State Model Synthesis of Active Distribution Networks
Abstract : With the increased penetration of distributed energy resources (DERs) at lower voltage levels, distribution networks (DNs) are being transformed into active grids. This has led to a paradigm shift in the operation, planning and control of DNs. READ MORE