Search for dissertations about: "shear failure"

Showing result 6 - 10 of 183 swedish dissertations containing the words shear failure.

  1. 6. Shear cracks in concrete structures subjected to in-plane stresses

    Author : Richard Malm; Håkan Sundquist; Kent Gylltoft; KTH; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; Shear; plane state stress; crack width; FE analysis; design standards; serviceability state; Civil engineering and architecture; Samhällsbyggnadsteknik och arkitektur;

    Abstract : After only two years of service, extensive cracking was found in the webs of two light-rail commuter line bridges in Stockholm, the Gröndal and Alvik bridges. Due to this incident it was found necessary to study the means available for analysing shear cracking in concrete structures subjected to in-plane stresses. READ MORE

  2. 7. Rock Mass Response to Coupled Mechanical Thermal Loading : Äspö Pillar Stability Experiment, Sweden

    Author : J. Christer Andersson; Håkan Stille; Charles Fairhurst; KTH; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; Yielding; Spalling; Rock mass strength; Confinement; Fracturing; Tensile failure; Shear failure; Displacement; Acoustic Emission; Heating; Stress; Back calculation; Radial expansion; Mining engineering; Gruvteknik;

    Abstract : The geological disposal of nuclear waste, in underground openings and the long-term performance of these openings demand a detailed understanding of fundamental rock mechanics. A full scale field experiment: Äspö Pillar Stability Experiment was conducted at a depth of 450 m in sparsely fractured granitic rock to examine the rock mass response between two deposition holes. READ MORE

  3. 8. Plug shear failure in nailed timber connections : avoiding brittle and promoting ductile failures

    Author : Helena Johnsson; Luleå tekniska universitet; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; Träbyggnad; Timber Structures;

    Abstract : Mechanical timber connections can fail both in a brittle and a ductile manner depending on the joint layout. Plug shear failure in nailed timber connections is a brittle failure mode, which shall be avoided in timber structures. READ MORE

  4. 9. Macroscale Modelling of 3D-Woven Composites: Inelasticity, Progressive Damage and Final Failure

    Author : Carolyn Oddy; Chalmers tekniska högskola; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; 3D-woven composites; Anisotropy; Damage; Inelasticity; Phase-field; Failure;

    Abstract : Composites with 3D-woven reinforcement have been slowly making their way into different industrial applications. The interlacement of yarns, not only in-plane but also through-thickness, means that in many applications 3D-woven composites can outperform their laminated counterparts. READ MORE

  5. 10. Shear Fracture and Delamination in Packaging Materials : A study of Experimental Methods and Simulation Techniques

    Author : Md. Shafiqul Islam; Sharon Kao-Walter; Christian Johansson; Johan Tryding; Blekinge Institute of Technology; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; Package opening; Shear test specimen; Stress intensity factor; Finite Element simulation; Scanning electron microscopy; Polymers; Interlaminar shear delamination;

    Abstract : Packages are the means of preservation, distribution and convenience of use for food, medicine and other consumer products. Package opening is becoming complicated in many cases because of cutting cost in design and production of opening techniques. READ MORE