Search for dissertations about: "ventilation ducts"

Showing result 1 - 5 of 9 swedish dissertations containing the words ventilation ducts.

  1. 1. Ventilation and window opening in schools, Experiments and Analysis

    Author : Birgitta Nordquist; Avdelningen för Installations- och klimatiseringslära; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; heat exchanger efficiency; duct design; balancing; disturbance; tracer gas measurements; analytical model; window opening; single-sided ventilation; ventilation; schools; sensitivity analysis; Building construction; Byggnadsteknik;

    Abstract : The objective of this thesis is to study the application of ventilation in schools buildings. A number of studies of the application of different forms of ventilation are presented. The main part of the thesis focuses on window opening in a classroom. Analytical models for calculation of the air change caused by window airing are proposed. READ MORE

  2. 2. Active Noise Control in Ventilation Systems : Practical Implementation Aspects

    Author : Martin Larsson; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY;

    Abstract : In many kinds of buildings, the ventilation is handled by a mechanical ventilation system. Such ventilation systems constitute a well known source of broadband noise. READ MORE

  3. 3. Laboratory Ventilation Systems: An Analysis of the Function and Flow Stability of Different Ductwork Design Alternatives

    Author : Madis Laaniste; Chalmers tekniska högskola; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; laboratory ventilation; transient flow simulation; fume hood;

    Abstract : One of the prerequisites for high safety in laboratories for chemical and microbiological research is a well-functioning ventilation system. The most typical safety measure in these laboratories is to use a fume hood as a place for activities that can cause dangerous emissions to the room air. READ MORE

  4. 4. Active Control of Noise in Ventilation Systems : Analysis and Experiments

    Author : Martin Larsson; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY;

    Abstract : In many kinds of buildings, the ventilation system constitute a well known source of broadband noise. Traditionally, duct born noise is attenuated using passive resistive silencers which produce a high level of attenuation over a broad frequency range. However, they tend to become large and bulky if designed for low frequency attenuation. READ MORE

  5. 5. Optimal damping and slow sound in ducts

    Author : Zhe Zhang; Mats Åbom; Hans Bodén; Lars Enghardt; KTH; []
    Keywords : TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; Vehicle and Maritime Engineering; Farkostteknik;

    Abstract : The thesis is dedicated to expanding knowledge on two duct acoustic issues including: 1) the optimal damping of low frequency sound and 2) the development and application of ‘slow sound’.To address the first issue, the ‘Cremer impedance’ proposed more than half a century ago has been revisited and further developed. READ MORE